ABB Robots
Overview
Copia can back up ABB IRC5 and IRC5P robot controllers over FTP or sFTP.
ABB robot projects use a File List to decide which files on the controller to include and exclude, and which files to leave out of the compare. Copia provides a default File List to get you started:
Copia - ABB Robot
Backs up everything in the Start Directory except log files, spreadsheets, PDFs and archives (
.log,.csv,.pdf,.zip,.7z,.xlsx).Compares the robot's program and configuration files:
.mod,.prg,.sys,.txt,.idand.cfg.Backs up but does not compare files that change on every backup, such as
BackInfo.txt.
More information about managing default File Lists and creating custom ones is covered in the File List section.
Supported controllers
IRC5
FTP or sFTP
IRC5P
FTP or sFTP
Which protocol a controller offers depends on its RobotWare version, its licensed options (for example FTP-1 or FTP-2) and your IT policy. Choose the protocol for each device when you set it up. It is recommended to use sFTP when the controller supports it.
Agent Requirements
On the robot controller:
FTP or sFTP is turned on.
You have the username and password of an account that can read the backup folder.
On the Agent machine:
The Agent machine can reach the controller on the network.
The Agent should be tested to confirm that it can reach the desired files with an FTP or sFTP client, using the same username, password and folder you will enter in Copia.
Project Configuration
To configure an ABB robot project, you need a repository with a folder to store the robot's backups. Give each robot its own folder, named after the robot or controller.
Click either of the Add a Project buttons in the Projects tab.

The Add a new project configuration dialog will appear which allows you to fully configure the project, devices and job for the project.

Define the Project
Select ABB Robot as the Project Type, then select an Agent. If you have not created an Agent yet, you can assign one later. See the Agents section of the documentation.
Press Save and Continue.

Select the Project Path: the repository and branch, then an existing folder or a new empty folder for this robot. Press Save and Continue.

The Project Details step lets you change the project name and add a description.
Select a File List. Start with Copia - ABB Robot. If your controller stores files the default list does not cover, or the compare shows changes you do not care about, make a copy of the default list and adjust it. See the File List section.
Press Save and Continue.

Device Configuration
Define the Device
Click Add a Device and fill in the controller's details. If you have pre-created devices, you can add existing devices instead.

Device Name
Yes
A name you will recognise, usually the robot or controller name, for example cell4-robot2.
Description
No
Any notes that help your team identify the robot.
Device Username
No
An account on the controller that can read the backup folder.
Device Password
No
That account's password.
Communication Path
No
The controller's IP address, for example 192.168.125.1.
Start Directory
No
The folder on the controller where the backup should begin. Leave blank to start in the login folder.
Protocol
Yes
sFTP (selected by default) or FTP. Choose the one your controller has turned on.
Press Save Device when complete.
Start Directory
By default, Copia begins each backup in the account's login folder on the controller and searches that folder and its subfolders. Use Start Directory to begin in the folder that holds the robot's backup instead. Starting in the right folder also makes each backup faster, because the Agent does not have to search the whole controller.
Note: If you leave this field blank, the backup will start in the default login folder.
Path formatting rules:
Always begin the path with
/and use/between folder names (for example/folder/subfolder). The leading/represents the account's login folder.Never include a drive letter such as
C:\or a controller drive name such asHOME:Do not use
.or..in your pathMatch the capitalization of the folder names on the controller exactly
For Example
If the robot's backup is saved in BACKUP/Robot2_Latest under the login folder:
✅ Correct:
/BACKUP/Robot2_Latest❌ Incorrect:
BACKUP/Robot2_Latest(the path must begin with/)❌ Incorrect:
/backup/robot2_latest(the capitalization must match the controller)
If the folder does not exist on the controller, the backup fails immediately, and the error message names the folder that could not be found.
Job Configuration
Define the Job
Creating Jobs is similar for all vendor types, and is described in the Creating Jobs section. You can create more than one job for a device if desired.

Submit the Configuration
Once complete, press Submit Project Setup to create the Project, Device(s) and Job(s).

Backup Results
What gets saved
Copia saves the files in the Start Directory and its subfolders that the File List includes, in the same folder structure as on the controller.
Up to Date or Modified
Up to Date: none of the compared files changed, so Copia keeps the previous version.
Modified: a compared file, such as a
.modprogram module or a.cfgconfiguration file, changed.
Files that are backed up but excluded from compare, such as BackInfo.txt, are still saved, but a change to them alone does not mark the backup as Modified.
Troubleshooting ABB Robot Backup Errors
No Files Were Backed Up
The backup connected to the controller but found no files to save. Unlike a generic FTP or sFTP project, an empty ABB backup is treated as a failure, because it almost always means the backup is pointed at the wrong place.
Resolution:
Check the Start Directory in the device settings. Make sure it begins with
/, matches the folder's capitalization, and points at the folder that holds the robot's backup.Check the File List. Patterns must be written as though the Start Directory were the top of the tree.
Sign in to the controller with an FTP or sFTP client from the Agent machine, using the same username and password, and confirm you can see the files.
Retry the backup.
Cannot Connect to the Controller
The Agent could not open a connection to the controller.
Resolution:
Check the Communication Path in the device settings.
Check the Protocol. If the device is set to sFTP but the controller only offers FTP, or the other way round, the connection fails. Change the protocol to the one the controller has turned on.
Check that the controller is reachable. On the Agent machine, open Command Prompt and run
pingwith the controller's address.If the controller answers but the connection still fails, a firewall may be blocking it. Ask your network team to allow TCP port 21 (FTP) or 22 (sFTP) from the Agent machine to the controller.
Retry the backup.
Invalid or Missing Protocol
The device does not have a valid protocol, so the Agent stopped the job. This can happen with devices created without a protocol value.
Resolution:
Open the device settings, choose FTP or sFTP under Protocol, and press Save Device.
Retry the backup.
Sending a Failed Backup to Copia Support
In Copia, open the failed job run.
Click Download Debug Files.
Send the file to Copia Support with a link to the job run.
Last updated