Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Siemens SCALANCE

Copia can back up the configuration of Siemens SCALANCE network switches. On each backup, the Copia Agent signs in to the switch, asks it to export its configuration, and saves the files to your Copia repository. Copia compares every backup with the one before, so you can see what changed on the switch and when.

Supported switches

Switch models
CLI Dialect

XB, XC, XP, XR, XM and W models

IOS

X-200, X-300 and X-400

Legacy

The two families use different command lines. The Agent detects which one your switch uses, so you do not need to choose.

How a backup works

  1. The Agent connects to the switch over SSH and signs in with the username and password you enter in Copia.

  2. The Agent asks the switch to send its configuration to the Agent machine.

  3. The switch sends the files to the Agent machine over TFTP, a simple file transfer built into the switch.

  4. Copia saves the files and compares them with the previous backup.

The Agent machine signs in to the switch over SSH and asks for an export, the switch sends its files back over TFTP, and the Agent uploads them to Copia over HTTPS
Steps 1, 2 and 4 go out from the Agent machine. Step 3 comes in to it.

Agent Requirements

Check these before you create the project. Most failed first backups come from one of them.

On the switch:

  • SSH is turned on. Telnet also works, but it sends the password unencrypted.

  • You have the username and password of an administrator account on the switch.

  • You have signed in with that account at least once. A new or reset switch asks you to change the default admin password at the first sign-in, and backups cannot run until you do.

On the Agent machine:

  • The Copia Agent is version 1.0.38 or later.

  • The Agent machine can reach the switch, and the switch can send to the Agent machine. This is the case when the Agent machine is on the plant network, even if people use a VPN to reach it.

  • Windows Firewall allows the switch's files in. See Allow SCALANCE backups through Windows Firewall below.

Allow SCALANCE backups through Windows Firewall

You need a Windows administrator for this, once per Agent machine.

The switch sends its files to UDP port 69 unless you set a different TFTP Port in the device settings. Use 69 unless another program on the Agent machine already uses it, such as another TFTP server. In that case, choose a free port, for example 10069, enter it as the device's TFTP Port, and use it instead of 69 below. To check whether port 69 is in use, run Get-NetUDPEndpoint -LocalPort 69 in PowerShell. No output means it is free.

The rule only lets your switches reach this port, and only the Agent can use it.

  1. On the Agent machine, press the Windows key, type Windows Defender Firewall with Advanced Security, and open it.

  2. In the left pane, click Inbound Rules. In the right pane, click New Rule.

  3. Choose Custom and click Next.

  4. Choose This program path, click Browse, and select dld.exe. By default it is in C:\Program Files\Copia Automation\Copia Agent\dld\. If you installed the Agent in a different folder, it is in the dld folder there. To check, open Services, double-click CopiaAgentService, and look at Path to executable. Click Next.

  5. Set Protocol type to UDP and Local port to Specific Ports, enter 69, and click Next.

  6. Under the remote IP addresses, choose These IP addresses, click Add, and enter the switch's IP address, for example 192.168.1.20. Add each switch the Agent backs up, or enter the plant network instead, for example 192.168.1.0/24. Click Next.

  7. Choose Allow the connection and click Next.

  8. Leave Domain, Private and Public ticked and click Next.

  9. Name the rule Copia Agent TFTP and click Finish.

If you prefer a command, open PowerShell as administrator and run the lines below. The command finds the Agent's install folder for you. Replace 192.168.1.20 with your switch's IP address. For several switches, separate the addresses with commas, or enter the plant network, for example 192.168.1.0/24.

The command does this for you, after it has found dld.exe. If it stops with an error, nothing was changed.

The Agent only listens on this port while a SCALANCE backup is running, and only accepts files from the switch being backed up.

If there is a firewall between the switch and the Agent machine, ask your network team to allow UDP on the same port from the switch to the Agent machine. If a router changes the switch's address on the way (NAT), allow the address the Agent machine sees instead of the switch's own.

When you add a switch with a new IP address, add it to the rule as well.

Verify the Agent machine can sign in to the switch

This optional check takes a minute and confirms the address, username and password before the first backup.

  1. On the Agent machine, open Command Prompt.

  2. Type ssh admin@192.168.1.20, using your switch's username and IP address, and press Enter. If you entered a port in the Communication Path, add it with -p, for example ssh -p 2222 admin@192.168.1.20.

  3. The first time, Windows asks if you want to continue connecting. Type yes and press Enter.

  4. Enter the password. If you see the switch's prompt, the details are correct. Type exit to leave.

If this fails, fix it first: the backup will fail the same way. If Command Prompt says 'ssh' is not recognized, this version of Windows has no SSH client, so skip this check.

Project Configuration

To configure a SCALANCE project, you need a repository with a folder to store the switch's backups. Give each switch its own folder, named after the switch.

The folder can be made during the project creation process.

Click either of the Add a Project buttons in the Projects tab.

The two Add a Project buttons on the Projects tab

The Add a new project configuration dialog will appear which allows you to fully configure the project, devices and job for the project.

Any items highlighted with an asterisk are required.

The Add a new project dialog with its five setup steps

Define the Project

Select Siemens SCALANCE as the Project Type, then select an Agent. If you have not created an Agent yet, you can assign one later. See the Agents section of the documentation.

Press Save and Continue.

Project Type set to Siemens SCALANCE

Select the Project Path: the repository and branch, then an existing folder or a new empty folder for this switch. Press Save and Continue.

The Project Path step, creating a new folder for the switch

The Project Details step lets you change the project name and add a description. Press Save and Continue.

Device Configuration

Define the Device(s)

Click Add a Device and fill in the switch's details. Only the first four fields are required. Leave the others blank unless one of the sections below says otherwise.

The Siemens SCALANCE Switch device form, filled in with the example values
The device form, filled in with the example values
Field
Required
What to enter

Device Name

Yes

A name you will recognise, for example line3-switch. Letters, numbers, dashes, underscores and dots only.

Communication Path

Yes

The switch's IP address, for example 192.168.1.20.

Device Username

Yes

An administrator account on the switch, for example admin.

Device Password

Yes

That account's password.

Protocol

No

Leave on SSH.

TFTP Server IP

No

Leave blank.

TFTP Port

No

Leave blank. The Agent uses port 69.

Export File Name

No

Leave blank to name the files after the device, or enter a name such as line3-switch.

CLI Dialect

No

Leave on Auto (default).

Press Save Device when complete.

Communication Path

Enter the switch's IP address, the one you would use to sign in to it.

  • ✅ 192.168.1.20

  • ✅ line3-switch.plant.local (a name your network translates to the switch's address)

  • ✅ 192.168.1.20:2222 (add a port only if the switch's SSH does not use the usual port 22)

  • ❌ https://192.168.1.20 (enter the address only, not a web link)

  • ❌ fe80::1 (IPv6 addresses are not supported; use the switch's IPv4 address)

Export File Name

This names the backup files. The Agent adds the endings itself. With line3-switch, an IOS switch saves line3-switch-running-config.txt and line3-switch-config.cfg.

  • ✅ line3-switch

  • ✅ Blank (the files are named after the device name)

  • ❌ line3-switch.cfg (the Agent adds the ending, so the file would be called line3-switch.cfg-config.cfg)

  • ❌ line3/switch (slashes are not allowed)

When to fill in the optional fields

Leave these fields blank, or on their default, unless one of these applies:

Field
Fill it in only when

Protocol

SSH cannot be turned on in the switch. Then choose Telnet, which sends the password unencrypted.

TFTP Server IP

The Agent machine has a VPN or a second network card, and the switch was given an address it cannot reach. The job log shows that address on the agent address the switch sends files to line. Enter the Agent machine's address on the switch's network. It must be one of the Agent machine's own addresses.

TFTP Port

Another program on the Agent machine already uses UDP port 69, such as another TFTP server, or your network only allows a different port. Allow the same port through Windows Firewall.

Export File Name

You want the file names to stay the same if the device is renamed in Copia, or the device name is longer than 21 characters on an X-200, X-300 or X-400.

CLI Dialect

A backup fails because the Agent could not identify the switch's command-line interface. Choose IOS for XB, XC, XP, XR, XM and W models, or Legacy for X-200, X-300 and X-400.

Job Configuration

Define the Job(s)

Creating Jobs is similar for all vendor types, and is described in the Creating Jobs section. You can create more than one job for a device if desired.

Submit the Configuration

Once complete, press Submit Project Setup to create the Project, Device(s) and Job(s).

Device and job set up, with the Submit Project Setup button

Don't forget to enable/disable the Watch button, based on your preferences for project Notifications.

Backup Results

What gets saved

File
What it is

<name>-running-config.txt

The switch's settings as a readable list of commands. Open this file to see what changed.

<name>-config.cfg

The switch's complete configuration file, exactly as the switch exported it. It is large, so the job page shows it folded with a warning icon. This is normal.

X-200, X-300 and X-400 switches export their whole configuration as one file, <name>-config.cfg.

The Agent saves the files exactly as the switch sends them and never edits them.

Up to Date or Modified

Every export contains a few lines that change on every backup: the switch's up time, its clock and two checksums. Copia ignores these lines when it decides whether anything changed.

  • Up to Date: nothing else changed, so Copia keeps the previous version.

  • Modified: a real setting changed. Copia saves the new files, and the changes appear in both of them. Those lines still show in the file comparison next to the real change, because the files are saved exactly as the switch sent them. This is expected.

Changes made by the backup itself

To export its configuration, the switch needs to know where to send the files. On every backup the Agent gives the switch its own address, the TFTP port and the file name, and the switch stores them in its settings. Those settings are part of the backup, so:

  • Changing the Export File Name or the TFTP Port appears as a change in the next backup.

  • So does moving the project to another Agent machine, or a new IP address on the Agent machine.

  • After you change the Export File Name, running-config.txt can still mention the old name in one backup. This is expected.

Troubleshooting SCALANCE Backup Errors

When a backup fails, the job run page explains what went wrong and what to do. Most errors are fixed by following that explanation. The errors below need more steps, and the job log shows the exact error quoted under each heading.

Connecting to the switch

Cannot Connect to the Switch

could not connect to the device

The Agent could not open a connection to the switch.

Resolution:

  1. Check the Communication Path in the device settings.

  2. Check that the switch is reachable. On the Agent machine, open Command Prompt and run ping 192.168.1.20 with the switch's address.

    • Replies mean the switch is on and the Agent machine can reach it.

    • Request timed out or Destination host unreachable means the switch is off, disconnected, or not reachable from the Agent machine. Check that it has power and a network connection, then ask your network team whether the Agent machine can reach that address.

    • The job log has the Agent's own result on the ICMP ping device line: recv=0 means none of its five pings were answered.

  3. If the switch answers, make sure SSH is turned on in the switch. If you chose Telnet, make sure Telnet is turned on.

  4. Verify the Agent machine can sign in to the switch. If the switch answers a ping but the sign-in fails, a firewall is probably blocking it. Ask your network team to allow TCP port 22 (SSH) or 23 (Telnet), or the port you entered in the Communication Path, from the Agent machine to the switch.

  5. Retry the backup.

Some networks block ping. If the ping fails but the sign-in in step 4 works, the switch is reachable and only ping is blocked.

The switch's SSH host key

These errors are about the switch's identity, called its SSH host key. The Agent records it on its first SSH backup and checks it on every later one, so a different device at the switch's address cannot receive the password.

Host Key Changed

the device's SSH host key does not match the one recorded

The switch presented a different identity than the one the Agent recorded. This is expected after the switch is replaced or reset to factory settings. It can also mean that another device is using the switch's address, so the Agent stopped before sending the password.

Resolution:

  1. Check with your network team that the switch was replaced or reset. If nobody knows why the key changed, investigate before you continue.

  2. Open the known_hosts file and delete the whole line that starts with the switch's address.

  3. Save the file and retry the backup. The Agent records the switch's new key.

Host Key Revoked

an SSH host key for the device is marked revoked in the agent's known hosts file

A line in the known_hosts file starts with @revoked and names this switch. Someone added it on purpose to block that key, so the Agent refuses to connect.

Resolution:

  1. Ask whoever manages the Agent machine why the key was revoked.

  2. If the switch is a replacement you have checked, open the known_hosts file and delete the @revoked line and every other line for the switch's address.

  3. Save the file and retry the backup. The Agent records the switch's new key.

known_hosts Access Error

could not read or update the agent's SSH known hosts file

There are two causes. The rest of the message in the job log tells you which one applies.

Cause 1: the account that runs the Agent changed. The message ends with something like:

opening C:\ProgramData\Copia Automation\Copia Agent SSH: Access is denied.

or, when the folder belongs to the previous account:

C:\ProgramData\Copia Automation\Copia Agent SSH is owned by CONTOSO\old-account, not SYSTEM, Administrators or the agent's account, …

To keep other users from adding their own keys, only SYSTEM, the Administrators group and the account that created the folder can open it. A new service account is therefore locked out. This often follows a change to the service's Log On account, for example as described in FactoryTalk Services Platform connection Error.

Resolution:

You need a Windows administrator on the Agent machine.

  1. Open Services, right-click CopiaAgentService and open Properties > Log On to find the account the service runs as. "Local System account" means SYSTEM. The Log On tab of the CopiaAgentService properties

  2. Open Command Prompt with Run as administrator and give that account Full control of the folder and the file in it. Replace CONTOSO\svc-copia with your service account: icacls "C:\ProgramData\Copia Automation\Copia Agent SSH" /grant "CONTOSO\svc-copia:F" /T

  3. Only if the error says the folder or file is owned by your previous service account, also make the Administrators group the owner of both: icacls "C:\ProgramData\Copia Automation\Copia Agent SSH" /setowner *S-1-5-32-544 /T

  4. Retry the backup. The Agent locks the folder and file again to SYSTEM, Administrators and the new account, and keeps every recorded and revoked key.

*S-1-5-32-544 is the Administrators group in every Windows language. If the error names an owner that has never run the Copia Agent, do not change the owner: contact Copia Support, because someone else may have created the folder with their own keys.

Cause 2: a line in the file is damaged. The message names a line number, such as known_hosts:1. This usually happens when part of a line was deleted by hand. One damaged line stops every SCALANCE backup on this Agent machine.

Resolution:

  1. Open the known_hosts file and delete that whole line.

  2. Save the file and retry the backup. If the line belonged to a switch, the Agent records that switch's key again on its next backup.

Editing the known_hosts File

  1. Press the Windows key and type Notepad. Right-click Notepad and choose Run as administrator.

  2. Choose File > Open. In the File name box, paste C:\ProgramData\Copia Automation\Copia Agent SSH\known_hosts and press Enter.

  3. Each line is one key. It starts with the switch's address as entered in Copia, followed by the key type and the key: 192.168.1.20 ecdsa-sha2-nistp521 AAAAE2VjZHNhLXNoYTItbmlzdHA1MjEAAAA... If you entered a port in the Communication Path, the line starts with [192.168.1.20]:2222 instead.

  4. Delete whole lines only. Never delete part of a line.

  5. Choose File > Save.

Receiving the files

No Windows Firewall Rule

no enabled Windows Firewall rule allows inbound UDP on the TFTP port

The switch could not send its files, and Windows Firewall on the Agent machine has no rule that lets them in.

Resolution:

  1. Add the rule described in Allow SCALANCE backups through Windows Firewall. Use the TFTP Port from the device settings, or 69 if it is blank.

  2. Retry the backup.

No Configuration File Arrived

no configuration file arrived over TFTP

The switch did not deliver its files to the Agent machine.

Resolution:

  1. Check that the Windows Firewall rule exists, is enabled, and allows this switch's address under remote addresses, either by its IP address or through a subnet that contains it. If a router changes the switch's address (NAT), the rule must allow the address the Agent machine sees instead. See Allow SCALANCE backups through Windows Firewall.

  2. Check that the switch can send to the Agent machine. A firewall or router between them must allow UDP on the TFTP port (69 by default) from the switch to the Agent machine.

  3. Check the address the switch was given, on the agent address the switch sends files to line of the job log. If it is a VPN address or another address the switch cannot reach, set TFTP Server IP to the Agent machine's address on the switch's network. See When to fill in the optional fields.

  4. Retry the backup.

When the Agent runs with administrator rights, as it does by default as a Windows service, it checks Windows Firewall for you and shows No Windows Firewall Rule if the rule is missing. Without administrator rights it cannot read the firewall settings, so a missing rule shows as this error instead.

TFTP Port Already in Use

TFTP port is already in use on the agent host

Another program on the Agent machine is using the TFTP port, often another TFTP server.

Resolution:

  1. Stop the other program, or

  2. Enter a free port in TFTP Port in the device settings, and allow that port through Windows Firewall.

  3. Retry the backup. A new port appears as a change in the next backup, as described in Changes made by the backup itself.

Sending a Failed Backup to Copia Support

  1. In Copia, open the failed job run.

  2. Click Download Debug Files.

  3. Send the file to Copia Support with a link to the job run.

For a failed backup, the debug files include a record of the Agent's conversation with the switch, with the password removed.

Last updated